Case Reports Open Access CC BY 4.0

Hemodynamic Management During Off-Pump Coronary Artery Bypass Grafting in a Patient with Left Ventricular Dysfunction and Elevated Pulmonary Artery Pressure: A Case Report

Fariz Wajdi Latuconsina1 , Reza Widianto Sudjud2 , Doddy Tavianto2
  1. Cardiovascular Anesthesia Trainee, Dr. Hasan Sadikin General Hospital, Bandung – Faculty of Medicine, Universitas Padjadjaran
  2. Consultant in Cardiovascular Anesthesia and Intensive Care, Department of Anesthesia and Intensive Care, Dr. Hasan Sadikin General Hospital, Bandung
First published: 20 November 2026
HTML XML

Abstract

Introduction: Off-pump coronary artery bypass grafting (OPCAB) poses hemodynamic challenges related to cardiac displacement and temporary coronary occlusion. These challenges are amplified in patients with left ventricular dysfunction and elevated pulmonary artery pressure.

Case Description: A 53-year-old man with three-vessel coronary artery disease and a left ventricular ejection fraction of 37.5% underwent OPCAB. After induction of anesthesia, pulmonary artery catheterization revealed a pulmonary artery pressure of 61/32 mmHg (mean 42 mmHg). Hemodynamics were optimized with dobutamine and nitroglycerin. During anastomosis of the left internal mammary artery to the left anterior descending artery, systemic pressure remained stable, and the mean pulmonary artery pressure decreased to 19 mmHg. Two episodes of significant hypotension occurred: during aortic side-biting clamp application (65/32 mmHg) and during distal anastomoses with cardiac displacement using a deep pericardial stitch (73/45 mmHg). Management comprised clamp repositioning, return of the heart to its anatomical position, and titration of vasoactive and inotropic support. Following release of the deep pericardial stitch, arterial pressure recovered to 126/69 mmHg with reduced norepinephrine requirements. The patient was extubated two hours postoperatively.

Conclusion: Both hypotensive episodes were temporally associated with surgical manipulation, suggesting reversible mechanical causes. A decrease in pulmonary artery pressure should not be interpreted as a reduction in pulmonary vascular resistance without concomitant wedge pressure and cardiac output measurements. Hemodynamic management during OPCAB requires evaluation of the temporal relationship between surgical maneuvers and circulatory changes, prompt correction of mechanical factors, and individualized pharmacological support.

Keywords: Off-Pump Coronary Artery Bypass, Left Ventricular Dysfunction, Pulmonary Artery Pressure, Deep Pericardial Stitch, Hemodynamic Management

Downloads

Download data is not yet available.

INTRODUCTION

Off-pump coronary artery bypass grafting (OPCAB) is a technique of myocardial revascularization performed on the beating heart without cardiopulmonary bypass. Surgical revascularization is an established strategy for multivessel coronary artery disease, with the choice of approach determined by coronary anatomy, clinical status, and Heart Team deliberation [1]. Although OPCAB avoids extracorporeal circulation, exposure of the target coronary arteries requires displacement of the heart. Elevation and rotation of the heart may distort cardiac chamber geometry, impair ventricular filling, and reduce stroke volume and cardiac output; these effects are particularly pronounced in patients with left ventricular dysfunction and limited contractile reserve [2,3].

Elevated pulmonary artery pressure further complicates hemodynamic management. In patients with left ventricular dysfunction, increased left-sided filling pressure may be transmitted retrogradely to the pulmonary circulation. However, pulmonary artery pressure is also determined by pulmonary vascular resistance and pulmonary blood flow; consequently, changes in pressure do not necessarily reflect changes in vascular resistance or right ventricular function [4,5]. Hemodynamic instability during OPCAB may result from mechanical disturbances related to cardiac manipulation, regional myocardial ischemia during temporary coronary occlusion, or changes in systemic vascular resistance. Identifying the underlying mechanism is essential for selecting the appropriate intervention, including correction of cardiac position and adjustment of pharmacological support [3]. This report describes the management of two intraoperative hypotensive episodes that were temporally associated with surgical maneuvers, and discusses the interpretation of pulmonary artery pressure changes, in a patient with left ventricular dysfunction undergoing OPCAB. This report was prepared in accordance with the CARE (CAse REport) guidelines.

CASE DESCRIPTION

A 53-year-old man (body weight 62 kg, height 165 cm) was scheduled for OPCAB for three-vessel coronary artery disease. He had a history of hypertension for more than ten years and a stroke two years earlier without residual neurological deficits. His chief complaints were exertional fatigue and chest pain for approximately seven months before surgery.

Coronary angiography revealed 95–99% proximal stenosis of the left anterior descending artery (LAD), 99–100% stenosis of the left circumflex artery (LCx), and total occlusion of the right coronary artery (RCA). Preoperative transthoracic echocardiography demonstrated a left ventricular ejection fraction (LVEF) of 37.5% by the Teichholz method, hypokinesia of the anterior and inferobasal walls, and left ventricular systolic and diastolic dysfunction. Chest radiography showed cardiomegaly with pulmonary congestion. The patient was classified as American Society of Anesthesiologists (ASA) physical status III. Preoperative characteristics are summarized in Table 1.

Table 1. Preoperative Characteristics of the Patient.

ParameterFinding
Age / sex53 years / male
Body weight / height62 kg / 165 cm
ComorbiditiesHypertension (>10 years); stroke 2 years earlier without residual deficit
SymptomsExertional fatigue and chest pain for ~7 months
Coronary angiographyProximal LAD stenosis 95–99%; LCx stenosis 99–100%; total RCA occlusion
Transthoracic echocardiographyLVEF 37.5% (Teichholz); anterior and inferobasal hypokinesia; LV systolic and diastolic dysfunction
Chest radiographyCardiomegaly with pulmonary congestion
ASA physical statusIII

Note : ASA, American Society of Anesthesiologists; LAD, left anterior descending artery; LCx, left circumflex artery; LV, left ventricular; LVEF, left ventricular ejection fraction; RCA, right coronary artery.

The anesthetic strategy aimed to maintain systemic and coronary perfusion pressure, avoid increases in myocardial oxygen demand, and anticipate impaired ventricular filling and contractility during cardiac manipulation. General anesthesia was induced with a remifentanil infusion (0.25 µg/kg/min), midazolam 6 mg, and rocuronium 60 mg, and maintained with sevoflurane at an inspired concentration of 2% in an oxygen–air mixture (FiO₂ 0.5). Transient hypotension to 85/55 mmHg during induction was treated with ephedrine 5 mg. Invasive monitoring was established with a radial arterial catheter and a pulmonary artery (Swan–Ganz) catheter. Initial measurements showed a pulmonary artery pressure (PAP) of 61/32 mmHg with a mean PAP (mPAP) of 42 mmHg, and a systemic arterial pressure of 122/68 mmHg with a mean arterial pressure (MAP) of approximately 90 mmHg. Dobutamine (3 µg/kg/min) and nitroglycerin (10 µg/min) were initiated for hemodynamic optimization, and a femoral arterial sheath was placed in anticipation of possible intra-aortic balloon pump (IABP) insertion. The intraoperative hemodynamic trend is shown in Figure 1, and key hemodynamic events are summarized in Table 2.

Figure 1. Intraoperative hemodynamic trend. ARTd, diastolic arterial pressure; ARTm, mean arterial pressure; ARTs, systolic arterial pressure; CVP, central venous pressure; HR, heart rate; PAPd, diastolic pulmonary artery pressure; PAPm, mean pulmonary artery pressure; PAPs, systolic pulmonary artery pressure; SpO₂, peripheral oxygen saturation.

During left internal mammary artery (LIMA)-to-LAD anastomosis, the heart was positioned with gauze pads and a cardiac tissue stabilizer. After dobutamine was increased to 5 µg/kg/min and nitroglycerin was reduced to 5 µg/min, systemic arterial pressure was stable at 119/72 mmHg, and the mPAP was recorded at 19 mmHg.

Table 2. Key Intraoperative Hemodynamic Events and Interventions.

Surgical stageArterial pressure (mmHg)PAP / mPAP (mmHg)Intervention and response
After induction (baseline)122/68 (MAP ~90)61/32 / 42Dobutamine 3 µg/kg/min and nitroglycerin 10 µg/min initiated; femoral sheath placed for possible IABP
LIMA–LAD anastomosis (stabilizer)119/72– / 19Dobutamine increased to 5 µg/kg/min; nitroglycerin reduced to 5 µg/min; stable
Aortic side-biting clamp application65/32 (nadir)–Clamp repositioned; arterial pressure recovered
Distal SVG anastomoses to PDA and diagonal (DPS)73/45 (nadir)–Trendelenburg ineffective; norepinephrine started
After DPS release126/69 (MAP 90)–Heart returned to anatomical position; norepinephrine requirement reduced
Before protamine109/56 (MAP 77)47/22 / 32CVP 15 mmHg
After protamine95/50 (MAP 67)40/21 / 28CVP 14 mmHg; norepinephrine increased to 0.1 µg/kg/min

Note : CVP, central venous pressure; DPS, deep pericardial stitch; IABP, intra-aortic balloon pump; LAD, left anterior descending artery; LIMA, left internal mammary artery; MAP, mean arterial pressure; mPAP, mean pulmonary artery pressure; PAP, pulmonary artery pressure; PDA, posterior descending artery; SVG, saphenous vein graft.

The first episode of significant hypotension occurred during application of a side-biting clamp on the ascending aorta for the proximal anastomoses, with arterial pressure falling to 65/32 mmHg. The surgeon suspected flow obstruction due to inappropriate clamp positioning, and the clamp was repositioned, after which arterial pressure recovered. The second episode occurred during saphenous vein graft anastomoses to the posterior descending artery (PDA) and the diagonal artery, when the heart was displaced using a deep pericardial stitch (DPS) without an apical suction device. Arterial pressure decreased to 73/45 mmHg. Trendelenburg positioning did not adequately restore arterial pressure; therefore, norepinephrine was initiated. After release of the DPS and return of the heart to its anatomical position, arterial pressure increased to 126/69 mmHg (MAP 90 mmHg), accompanied by a reduction in norepinephrine requirements. Anticoagulation with unfractionated heparin 3 mg/kg (180 mg) increased the activated clotting time (ACT) from 154 to 798 seconds. After completion of revascularization, protamine 90 mg was administered, and the ACT decreased to 124 seconds. Before protamine administration, arterial pressure was 109/56 mmHg (MAP 77 mmHg), PAP was 47/22 mmHg (mPAP 32 mmHg), and central venous pressure (CVP) was 15 mmHg. After protamine, these values were 95/50 mmHg (MAP 67 mmHg), 40/21 mmHg (mPAP 28 mmHg), and 14 mmHg, respectively, and norepinephrine was increased to 0.1 µg/kg/min. Estimated intraoperative blood loss was 900 mL, and the operation lasted approximately 3 hours and 10 minutes. The patient was transferred to the intensive care unit (ICU) on dobutamine 5 µg/kg/min and norepinephrine 0.1 µg/kg/min, and was extubated approximately two hours after the end of surgery.

DISCUSSION

Multivessel coronary artery disease limits myocardial perfusion reserve and increases vulnerability to ischemia when coronary perfusion pressure falls or myocardial oxygen demand rises. In patients with left ventricular dysfunction, limited contractile reserve aggravates the risk of reduced stroke volume in response to changes in preload, afterload, and contractility during anesthesia and cardiac manipulation [2]. In this patient, a preoperative LVEF of 37.5% indicated impaired systolic function, while accompanying diastolic dysfunction increased sensitivity to alterations in ventricular filling. During OPCAB, elevation and rotation of the heart may reduce effective left ventricular filling even when measured filling pressures do not decrease [3].

The LVEF in this case was derived using the Teichholz method, which estimates ventricular volumes from linear dimensions. In patients with regional wall motion abnormalities, this method is limited because it assumes uniform ventricular geometry and contraction. The American Society of Echocardiography and European Association of Cardiovascular Imaging recommend volumetric methods, such as the biplane method of disks (modified Simpson's rule), whenever image quality permits [6]. The LVEF in this case should therefore be regarded as an estimate of systolic function; nevertheless, the combination of severe coronary disease, regional wall motion abnormalities, and ventricular dysfunction indicated a high susceptibility to intraoperative hemodynamic instability. The initial pulmonary artery catheter measurement showed an mPAP of 42 mmHg. According to the 2022 ESC/ERS guidelines, pulmonary hypertension is hemodynamically defined as an mPAP greater than 20 mmHg at rest, as measured by right heart catheterization. Classification of its mechanism requires measurement of pulmonary artery wedge pressure (PAWP) and pulmonary vascular resistance (PVR) [4]. In patients with left ventricular systolic and diastolic dysfunction, elevated left-sided filling pressure may be transmitted to the pulmonary circulation, and the preoperative radiographic pulmonary congestion supports a possible post-capillary contribution. Without PAWP and PVR measurements, however, this mechanism cannot be confirmed [5]. Moreover, measurements obtained after induction under positive-pressure ventilation may not be directly comparable with resting values.

After dobutamine and nitroglycerin administration, the mPAP decreased from 42 to 19 mmHg during LIMA–LAD anastomosis. This change requires cautious interpretation because PAP is determined by left-sided filling pressure, PVR, and pulmonary blood flow, a relationship summarized by the equation PVR = (mPAP − PAWP) / CO, where CO is cardiac output [4]. Accordingly, a decrease in mPAP may result from a reduction in PAWP, a reduction in PVR, a reduction in pulmonary blood flow, or a combination of these mechanisms [4]. Nitroglycerin may lower cardiac filling pressures through venodilation, whereas dobutamine increases myocardial contractility and may alter cardiac output; the PAP response to these agents alone, however, cannot determine the mechanism of the hemodynamic change. Cardiac displacement during OPCAB may also affect pulmonary blood flow and ventricular filling, such that reduced right ventricular output can lower PAP even as systemic perfusion deteriorates [2]. Right ventricular function cannot be assessed on the basis of PAP alone. The 2025 American Society of Echocardiography guidelines emphasize a comprehensive assessment of right ventricular size, geometry, systolic function, and loading conditions [7]. These guidelines update the 2010 recommendations, which established parameters such as tricuspid annular plane systolic excursion and fractional area change [8]. In this case, systemic arterial pressure was relatively stable during LIMA–LAD anastomosis when the mPAP was 19 mmHg. This finding indicates that systemic perfusion pressure was maintained at that time, but it does not establish an increase in cardiac output, a reduction in PVR, or an improvement in right ventricular function. Changes in PAP during OPCAB should therefore be interpreted together with systemic arterial pressure, CVP, clinical status, the stage of cardiac manipulation, and flow-based parameters whenever available.

Hemodynamic instability during OPCAB may arise through different mechanisms at different surgical stages. Elevation and rotation of the heart may distort chamber geometry, impair ventricular filling, and reduce stroke volume and cardiac output, whereas temporary coronary occlusion during anastomosis may cause regional myocardial ischemia that further impairs contractility [3]. In this patient, the two hypotensive episodes showed distinct temporal relationships with surgical maneuvers (Table 2). The first episode occurred immediately after application of the aortic side-biting clamp, when arterial pressure fell to 65/32 mmHg. Its abrupt onset raised suspicion of mechanical obstruction of aortic flow, and the recovery of arterial pressure after clamp repositioning supports a mechanical contribution. In the absence of simultaneous aortic flow or cardiac output measurements, however, this mechanism cannot be confirmed definitively. In practice, a transient reduction in systolic pressure is often requested before side-biting clamp application to reduce the risk of aortic injury, which further narrows the margin of safety in patients with limited cardiac reserve [2]. The second episode occurred during distal anastomoses to the posterior and diagonal territories, when the heart was elevated and rotated using a DPS. Such manipulation can alter atrioventricular geometry, impair effective ventricular filling, and reduce stroke volume, even when measured filling pressures increase because of chamber compression. Chang et al. reported that the use of a DPS during posterior vessel anastomosis produced greater reductions in cardiac index and stroke volume index than a vacuum-assisted apical suction device [9]. Using three-dimensional echocardiography, George et al. demonstrated that both positioning techniques alter cardiac chamber geometry, with distinct patterns of ventricular dysfunction [10]. Abicht et al. likewise reported differing hemodynamic responses to the two techniques during exposure of the lateral and posterior coronary vessels [11]. Collectively, these studies indicate that the hemodynamic impact depends not only on the positioning technique but also on the degree of elevation and rotation, the anastomotic site, and baseline ventricular function. Neither technique has shown consistent hemodynamic superiority across all surgical conditions [9].

In the present case, hypotension during distal anastomosis responded inadequately to Trendelenburg positioning, whereas release of the DPS and return of the heart to its anatomical position restored arterial pressure to 126/69 mmHg with a reduced norepinephrine requirement. This temporal relationship supports a mechanical contribution related to cardiac displacement. Nevertheless, recovery after repositioning does not prove that impaired ventricular filling was the sole cause, as regional ischemia, altered contractility, and changes in systemic vascular resistance may have contributed concurrently. Continuous invasive arterial pressure monitoring enabled early detection of hypotension during cardiac manipulation, and the pulmonary artery catheter provided additional information on pulmonary and central venous pressures. Pressure parameters, however, do not directly reflect blood flow; for example, CVP may increase because of impaired right ventricular filling or emptying even as cardiac output decreases [3]. In this case, the absence of intraoperative cardiac output, PAWP, and PVR measurements limited mechanistic interpretation, and the lack of transesophageal echocardiography precluded evaluation of chamber geometry, biventricular function, and new regional wall motion abnormalities. Comprehensive echocardiographic assessment can help distinguish changes in intrinsic ventricular function from changes in loading conditions [7]. Pharmacological support was tailored to the prevailing hemodynamic state: dobutamine supported myocardial contractility, nitroglycerin was used as part of hemodynamic optimization, and norepinephrine was administered during hypotensive episodes to maintain systemic perfusion pressure. An increase in arterial pressure after vasopressor administration, however, does not necessarily indicate improved cardiac output. When hypotension is predominantly mechanical, correction of clamp or cardiac position should be considered alongside pharmacological support [2]. In this case, the recovery of arterial pressure after clamp repositioning and after return of the heart to its anatomical position underscores the importance of evaluating the temporal relationship between surgical maneuvers and hemodynamic changes. Close communication between the anesthesia and surgical teams is essential to identify correctable factors. Placement of a femoral sheath in anticipation of IABP insertion, together with the readiness to convert to cardiopulmonary bypass, represents a prudent contingency plan in patients with reduced ventricular function [2].

Heparin anticoagulation is required during OPCAB to reduce the risk of thrombosis during coronary anastomosis, and reversal with protamine follows completion of revascularization. The 2024 EACTS/EACTAIC guidelines on patient blood management emphasize individualized protamine dosing to avoid both residual anticoagulation and protamine-induced coagulopathy from overdosing [12]. In this case, protamine 90 mg was administered after heparin 180 mg, corresponding to a protamine-to-heparin ratio of 0.5:1, and the ACT decreased from 798 to 124 seconds. These findings support effective reversal of anticoagulation as assessed by ACT, although they do not confirm normalization of all components of hemostasis. The modest decline in arterial and pulmonary pressures after protamine administration, which required an increase in norepinephrine, was consistent with the recognized vasodilatory effects of protamine administration. The principal limitation of this report is the absence of intraoperative cardiac output, PAWP, and PVR measurements, as well as of transesophageal echocardiography. Consequently, the mechanisms underlying the elevated PAP and the hypotensive episodes during cardiac manipulation could not be determined definitively. Interpretation therefore relied mainly on the temporal relationship between surgical maneuvers, pressure changes, and the response to interventions. This case nonetheless illustrates that measured pressure changes do not necessarily reflect changes in blood flow, and that evaluation of hemodynamic stability during OPCAB should consider potentially correctable mechanical disturbances in addition to the need for pharmacological support.

CONCLUSION

In OPCAB with left ventricular dysfunction, hypotension may have a correctable mechanical cause related to surgical manipulation. Pulmonary artery pressure changes should be interpreted together with flow parameters and ventricular function, and close anesthesia–surgical coordination is essential.

DECLARATIONS

None

CONSENT FOR PUBLICATION

The Authors agree to be published in the Journal of Society Medicine.

FUNDING

None

COMPETING INTERESTS

The authors declare no conflicts of interest in this case report.

AUTHORS’ CONTRIBUTIONS

All authors read and approved the final version of the manuscript and agree to be accountable for all aspects of the work.

ACKNOWLEDGMENTS

The authors gratefully acknowledge the patient for his consent to share this case for educational purposes. The authors also thank the cardiothoracic surgical team, the cardiac anesthesia team, the perfusionists, and the intensive care unit and nursing staff of Dr. Hasan Sadikin General Hospital, Bandung, for their collaboration in the perioperative care of this patient.

REFERENCE

Similar Articles

<< < 13 14 15 16 17 18 

You may also start an advanced similarity search for this article.